{"id":5616,"date":"2026-11-04T00:00:39","date_gmt":"2026-11-03T16:00:39","guid":{"rendered":"https:\/\/www.jortangroup.com\/?p=5616"},"modified":"2026-11-06T15:10:46","modified_gmt":"2026-11-06T07:10:46","slug":"how-to-correct-timestamp-drift-across-cameras-and-nvrs-before-handover","status":"publish","type":"post","link":"https:\/\/www.jortangroup.com\/fr\/how-to-correct-timestamp-drift-across-cameras-and-nvrs-before-handover\/","title":{"rendered":"Comment corriger la d\u00e9rive d'horodatage entre les cam\u00e9ras et les NVR avant le transfert"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter  wp-image-5600\" src=\"http:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover.jpg\" alt=\"How to Correct Timestamp Drift Across Cameras and NVRs Before Handover\" width=\"723\" height=\"510\" srcset=\"https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover.jpg 850w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover-300x212.jpg 300w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover-768x542.jpg 768w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover-18x12.jpg 18w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/How-to-Correct-Timestamp-Drift-Across-Cameras-and-NVRs-Before-Handover-600x424.jpg 600w\" sizes=\"(max-width: 723px) 100vw, 723px\" \/><\/p>\n<p>Rembobinez l'\u00e9v\u00e9nement d'hier \u00e0 14h32 sur toutes les cam\u00e9ras concern\u00e9es. Mais que faire en cas de d\u00e9rive d'horodatage\u00a0? L'enregistrement existe peut-\u00eatre, mais il est inaccessible car il se trouve dans une fen\u00eatre inaccessible, ou deux cam\u00e9ras enregistrent le m\u00eame \u00e9v\u00e9nement \u00e0 plusieurs minutes d'intervalle. L'horodatage est \u00e9galement essentiel pour les preuves. Les clips export\u00e9s sont accompagn\u00e9s de journaux syst\u00e8me et de m\u00e9tadonn\u00e9es lisibles par machine permettant \u00e0 l'\u00e9quipe de v\u00e9rification de les confirmer. Un horodatage manifestement erron\u00e9 compromet l'ensemble du dossier. La d\u00e9rive passe inaper\u00e7ue pendant des semaines, puis se manifeste soudainement lors de la validation. La proc\u00e9dure de correction ci-dessous permet de corriger l'ensemble du parc de cam\u00e9ras en une seule session.<\/p>\n<h2><strong><b>O\u00f9 le <\/b><\/strong><strong><b>D<\/b><\/strong><strong><b>crevasse <\/b><\/strong><strong><b>C<\/b><\/strong><strong><b>grand-m\u00e8re <\/b><\/strong><strong><b>F<\/b><\/strong><strong><b>rom<\/b><\/strong><\/h2>\n<p><a href=\"https:\/\/www.jortangroup.com\/fr\/ip-camera\/\"><strong><u><b>Une cam\u00e9ra IP<\/b><\/u><\/strong><\/a>\u00a0Le syst\u00e8me utilise un oscillateur temps r\u00e9el bon march\u00e9 pour maintenir l'heure, et celle-ci d\u00e9rive sensiblement au fil des semaines sans aucune correction. Une cam\u00e9ra mise en service lors de la premi\u00e8re semaine du projet et jamais utilis\u00e9e sera en d\u00e9calage avec une cam\u00e9ra ajout\u00e9e lors de la neuvi\u00e8me semaine. \u00c0 ce d\u00e9calage temporel s'ajoutent des erreurs de configuration. Le protocole NTP n'est jamais activ\u00e9 ou est configur\u00e9 pour pointer vers un serveur inaccessible au r\u00e9seau du site. Les fuseaux horaires sont param\u00e9tr\u00e9s cam\u00e9ra par cam\u00e9ra par diff\u00e9rents installateurs \u00e0 des dates diff\u00e9rentes. La gestion de l'heure d'\u00e9t\u00e9 est appliqu\u00e9e au niveau du NVR, mais pas aux cam\u00e9ras. Certaines unit\u00e9s perdent l'heure enregistr\u00e9e apr\u00e8s une mise \u00e0 jour du firmware ou leur horloge ne se synchronise pas apr\u00e8s un red\u00e9marrage sans batterie. Il existe \u00e9galement un pi\u00e8ge structurel qu'il convient de mentionner\u00a0: une cam\u00e9ra synchronis\u00e9e avec une plateforme plut\u00f4t qu'avec le protocole NTP sera d\u00e9cal\u00e9e par rapport au NVR du rack lorsque les deux appareils fonctionnent sur des bases de temps diff\u00e9rentes. Les deux appareils apparaissent alors synchronis\u00e9s sur leurs \u00e9crans respectifs, tandis que leurs enregistrements divergent.<\/p>\n<h2><strong><b>Le <\/b><\/strong><strong><b>S<\/b><\/strong><strong><b>Inc <\/b><\/strong><strong><b>LE<\/b><\/strong><strong><b>order cela <\/b><\/strong><strong><b>H<\/b><\/strong><strong><b>vieux<\/b><\/strong><\/h2>\n<p>Configurez la source de temps avant de modifier le comportement de chaque cam\u00e9ra. La cha\u00eene de synchronisation comporte trois maillons\u00a0: un serveur NTP faisant autorit\u00e9 et accessible depuis le r\u00e9seau (serveur interne sur les r\u00e9seaux ferm\u00e9s ou serveur mutualis\u00e9 autorisant les connexions sortantes). <a href=\"https:\/\/www.jortangroup.com\/fr\/monitoring-package\/nvr\/\"><strong><u><b>Le NVR<\/b><\/u><\/strong><\/a>\u00a0Synchronisation avec ce serveur. Chaque cam\u00e9ra doit \u00eatre synchronis\u00e9e avec le m\u00eame serveur, et non avec l'interpr\u00e9tation de celui-ci par le NVR. De nos jours, la plupart des NVR proposent des champs directement accessibles dans les param\u00e8tres r\u00e9seau, et un serveur NTP y est int\u00e9gr\u00e9. Il est imp\u00e9ratif de v\u00e9rifier la synchronisation des deux c\u00f4t\u00e9s apr\u00e8s chaque modification, car lorsqu'une cam\u00e9ra ne parvient pas \u00e0 joindre le serveur, elle bascule silencieusement sur son horloge interne. Elle lira alors l'heure conform\u00e9ment \u00e0 votre configuration, c'est-\u00e0-dire qu'elle ne fera rien. Effectuez la synchronisation de l'ensemble du parc en une seule op\u00e9ration, sur tous les appareils, avec le m\u00eame fuseau horaire et la m\u00eame politique d'heure d'\u00e9t\u00e9, et en utilisant la m\u00eame cha\u00eene de serveur NTP sur chaque appareil. Ensuite, au lieu de comparer chaque appareil entre eux, centralisez la synchronisation dans une r\u00e9f\u00e9rence commune. Une synchronisation partielle est pire que l'absence de synchronisation. Elle cr\u00e9e pr\u00e9cis\u00e9ment le d\u00e9calage entre les cam\u00e9ras qui perturbe la lecture corr\u00e9l\u00e9e, et elle masque ce d\u00e9calage au sein d'un parc qui semble pourtant parfaitement configur\u00e9.<\/p>\n<h2><strong><b>Quoi <\/b><\/strong><strong><b>R<\/b><\/strong><strong><b>restes <\/b><\/strong><strong><b>DANS<\/b><\/strong><strong><b>Rong <\/b><\/strong><strong><b>UN<\/b><\/strong><strong><b>apr\u00e8s un <\/b><\/strong><strong><b>P<\/b><\/strong><strong><b>parfait <\/b><\/strong><strong><b>S<\/b><\/strong><strong><b>Inc<\/b><\/strong><\/h2>\n<p>L'\u00e9tape de correction, par exemple, modifie l'heure pour les donn\u00e9es futures, tandis que les enregistrements plus anciens conservent leurs horodatages. Les donn\u00e9es enregistr\u00e9es lorsque les horloges \u00e9taient d\u00e9synchronis\u00e9es portent des horodatages erron\u00e9s\u00a0; par cons\u00e9quent, les \u00e9v\u00e9nements survenus pendant une p\u00e9riode de d\u00e9calage sont localis\u00e9s en effectuant une recherche dans une fen\u00eatre temporelle beaucoup plus large, et ces informations doivent figurer dans votre document de transfert. Les sites connect\u00e9s \u00e0 une plateforme n\u00e9cessitent une v\u00e9rification suppl\u00e9mentaire. Un projet d\u00e9ploy\u00e9 sur une plateforme de type GB\/T28181, telle que\u2026 <a href=\"https:\/\/www.jortangroup.com\/fr\/\"><strong><u><b>Jordanie<\/b><\/u><\/strong><\/a>Par exemple, le syst\u00e8me horodate les flux vid\u00e9o des cam\u00e9ras pour l'enregistrement et le transport en fonction du domaine d'horloge de la plateforme, ce qui permet \u00e9galement de v\u00e9rifier la couche plateforme. La synchronisation entre la cam\u00e9ra et le NVR n'est cependant qu'une \u00e9tape de plus.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5612\" src=\"http:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/crowds-in-the-camera-footage.jpg\" alt=\"crowds in the camera footage\" width=\"500\" height=\"400\" srcset=\"https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/crowds-in-the-camera-footage.jpg 500w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/crowds-in-the-camera-footage-300x240.jpg 300w, https:\/\/www.jortangroup.com\/wp-content\/uploads\/2026\/11\/crowds-in-the-camera-footage-15x12.jpg 15w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<p>La d\u00e9rive n'est pas un probl\u00e8me ponctuel. Une cam\u00e9ra qui red\u00e9marre (red\u00e9marrage du syst\u00e8me de surveillance, cycle programm\u00e9 de commutation PoE, temp\u00eate) pr\u00e9sente une nouvelle d\u00e9rive d\u00e8s que le protocole NTP cesse de fonctionner, et ce dysfonctionnement est souvent silencieux. La v\u00e9rification doit \u00eatre effectu\u00e9e r\u00e9guli\u00e8rement, au minimum une fois par mois, et non pas seulement lors de la semaine de mise en service. Le contrat de maintenance est la solution id\u00e9ale, avec un tarif \u00e9quivalent \u00e0 celui du service de nettoyage des objectifs.<\/p>\n<h2><strong><b>Le <\/b><\/strong><strong><b>ET<\/b><\/strong><strong><b>connaissance <\/b><\/strong><strong><b>P<\/b><\/strong><strong><b>retour \u00e0 <\/b><\/strong><strong><b>H<\/b><\/strong><strong><b>Andover<\/b><\/strong><\/h2>\n<p>Avant la signature, effectuez un test d'acceptation corr\u00e9l\u00e9. D\u00e9clenchez un \u00e9v\u00e9nement visible unique dans le champ de vision superpos\u00e9 de deux cam\u00e9ras ou plus, pendant que le NVR enregistre la sc\u00e8ne. R\u00e9cup\u00e9rez la lecture de cet \u00e9v\u00e9nement depuis chaque source. V\u00e9rifiez que les heures de superposition concordent \u00e0 une ou deux secondes pr\u00e8s. Capturez une capture d'\u00e9cran de la comparaison. Enregistrez la cha\u00eene de caract\u00e8res du serveur NTP et l'\u00e9tat de synchronisation de chaque appareil pour l'ensemble du parc. Archivez ces informations dans le dossier de transfert. Ce document d'une page r\u00e9pond \u00e0 la question pos\u00e9e lors de chaque audit ult\u00e9rieur\u00a0: l'heure du syst\u00e8me \u00e9tait-elle correcte le jour en question\u00a0? Qui l'a v\u00e9rifi\u00e9e et \u00e0 quel moment\u00a0?<\/p>\n<h2><strong><b>Conclusion<\/b><\/strong><\/h2>\n<p>Le d\u00e9calage temporel reste imperceptible jusqu'\u00e0 ce que la lecture ne corresponde plus \u00e0 l'heure de l'\u00e9v\u00e9nement demand\u00e9. Il interrompt la lecture corr\u00e9l\u00e9e lors du transfert et compromet les preuves export\u00e9es ult\u00e9rieurement. De plus, il s'accumule silencieusement sur tout appareil dont l'\u00e9tat NTP a \u00e9t\u00e9 pr\u00e9sum\u00e9 plut\u00f4t que relu. La proc\u00e9dure de correction est simple\u00a0: une source NTP unique et accessible \u00e0 tous, le m\u00eame fuseau horaire et la m\u00eame politique d'heure d'\u00e9t\u00e9 pour l'ensemble du parc, la synchronisation des cam\u00e9ras sur cette horloge d\u00e9di\u00e9e (et non entre elles), puis un test de lecture multicam\u00e9ra avec les donn\u00e9es corr\u00e9l\u00e9es, le tout \u00e9tant enregistr\u00e9 comme preuve de validation. La fr\u00e9quence de ce contr\u00f4le doit \u00eatre d'au moins une fois par mois. Il est donc conseill\u00e9 de l'int\u00e9grer au planning de maintenance d\u00e8s la premi\u00e8re semaine, car, \u00e9tant donn\u00e9 que le parc peut pr\u00e9senter des dysfonctionnements (bons et mauvais) sans que personne ne s'en aper\u00e7oive d'une semaine \u00e0 l'autre (semaine 1) pendant environ neuf semaines, personne dans le b\u00e2timent ne remarquera le probl\u00e8me.\u00a0<a href=\"https:\/\/www.jortangroup.com\/fr\/contact-us\/\"><strong><u><b>N'h\u00e9sitez pas \u00e0 nous contacter<\/b><\/u><\/strong><\/a>.<\/p>\n<h2><strong><b>FAQ<\/b><\/strong><\/h2>\n<p><strong><b>Q1\u00a0: Les cam\u00e9ras doivent-elles se synchroniser avec le NVR ou avec un serveur NTP\u00a0?<\/b><\/strong><\/p>\n<p>A1\u00a0: Au m\u00eame serveur NTP que celui utilis\u00e9 par le NVR, lorsque la cam\u00e9ra prend en charge NTP. Le cha\u00eenage des cam\u00e9ras sur l\u2019horloge du NVR ajoute un saut, et sur les parcs de cam\u00e9ras mixtes, cela cr\u00e9e deux bases de temps qui semblent correctes chacune, mais qui sont en d\u00e9saccord l\u2019une avec l\u2019autre.<\/p>\n<p><strong><b>Q2\u00a0: Pourquoi une cam\u00e9ra d\u00e9rive-t-elle alors que les autres restent correctes\u00a0?<\/b><\/strong><\/p>\n<p>A2\u00a0: Cette cam\u00e9ra ne parvient g\u00e9n\u00e9ralement pas \u00e0 se connecter au serveur NTP (probl\u00e8me de routage, VLAN ou pare-feu) et a bascul\u00e9 silencieusement sur son horloge interne. Une mise \u00e0 jour du micrologiciel r\u00e9initialisant les param\u00e8tres d'heure est l'autre possibilit\u00e9. L'\u00e9tat de la synchronisation est lu individuellement pour chaque appareil et n'est jamais d\u00e9duit du lot.<\/p>\n<p><strong><b>Q<\/b><\/strong><strong><b>3<\/b><\/strong><strong><b>Comment un projet prouve-t-il l'exactitude de l'horodatage lors de son acceptation\u00a0?<\/b><\/strong><\/p>\n<p>A3 : Enregistrez un \u00e9v\u00e9nement simultan\u00e9 sur deux cam\u00e9ras ou plus et le NVR, comparez les temps de superposition dans la lecture captur\u00e9e, puis joignez les captures d'\u00e9cran et les pages d'\u00e9tat NTP par appareil au pack de transfert en tant qu'\u00e9l\u00e9ment d'horodatage.<\/p>","protected":false},"excerpt":{"rendered":"<p>Rembobinez l'\u00e9v\u00e9nement d'hier \u00e0 14h32 sur toutes vos cam\u00e9ras concern\u00e9es. Mais que faire si le site pr\u00e9sente des probl\u00e8mes de d\u00e9rive d'horodatage\u00a0? Par exemple, si l'enregistrement existe mais se trouve dans une fen\u00eatre inaccessible, ou si deux cam\u00e9ras enregistrent le m\u00eame \u00e9v\u00e9nement \u00e0 plusieurs minutes d'intervalle\u00a0? L'horodatage est \u00e9galement essentiel pour les preuves. En effet, les clips export\u00e9s [\u2026]<\/p>","protected":false},"author":1,"featured_media":5600,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37],"tags":[],"class_list":["post-5616","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/posts\/5616","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/comments?post=5616"}],"version-history":[{"count":3,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/posts\/5616\/revisions"}],"predecessor-version":[{"id":5633,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/posts\/5616\/revisions\/5633"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/media\/5600"}],"wp:attachment":[{"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/media?parent=5616"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/categories?post=5616"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jortangroup.com\/fr\/wp-json\/wp\/v2\/tags?post=5616"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}